White-Rodgers 1F89-0211 Non-Programmable Heat Pump Thermostat
About This Thermostat
| MFG: | White-Rodgers |
| MFG#: | 1F89-0211 |
| Our#: | 175117 |
| Programmable: | No |
| Stages: | 2H & 1C |
| System Compatibility: | Heat Pump, Millivolt |
| Power Options: | 24 VAC Hardwire |
| Heat/Cool Changeover: | Manual |
| Programmable Fan: | No |
| Temperature Limits: | No |
| Keypad Lockout: | No |
| Backlight: | Yes |
| Vacation Hold: | No |
Replaces 1F89-211
Features:
Display
- Easy-to-read LCD with improved contrast
- Lighted display for easier low-light viewing
Comfort & Convenience
- Permanent program retention during power loss
- Setpoint Hold
- Simple "setup" menu to activate optional features
- Temporary temperature override two-hour minimum or until next program period
- Soft-touch keypad
- Display temperature recalibration (+/- 4°)
- Easy access battery compartment
Performance
- Dual-Powered. Choice of battery-powered or hardwired, for all applications
- Selectable Energy Management Recovery
- Meets ENERGY STAR® specifications
- Meets California Building Code, Title 24
- Fast (FA) or slow (SL) heating cycle anticipation
- Easy-to-wire push-connect color coded terminals
- Compressor lockout protection
- Millivolt compatible
- Electric heat option
SPECIFICATIONS
Electrical Rating:
Dual Power or Battery Power Model . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire Model . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . 1.5 A per terminal, 2.5A maximum all terminals combined
Setpoint Temperature Range . . . . . . . . . . . 45 to 90°F (7 to 32°C)
Anticipation, Heating . . . . . . . . . . . . . . . . . . Adjustable
Anticipation, Cooling . . . . . . . . . . . . . . . . . . Fixed
Rated Differential, Heat . . . . . . . . . . . . . . . 0.8° or 1.2°F
Rated Differential, Cool . . . . . . . . . . . . . . . . 1.2°F
Operating Ambient Temperature Range . . . 32 to 105°F (0 to 41°C)
Operating Humidity Range . . . . . . . . . . . . . 0-90% RH noncondensing
Shipping Temperature Range . . . . . . . . . . . -40 to +150°F (-40 to +65°C)
Dimensions . . . . . . . . . . . . . . . . . . 3-3/4"H x 4-3/4"W x 1-1/2"D
Terminals: R, C, Y, W2, G, O/B, L
Reviewed by 1 customer
Displaying review 1
Pros
- Easy To Adjust
- Intuitive Controls
- Precise Controls
Cons
- None
Best Uses
- Central Controls
- Homes
- Large Rooms
- Offices
Comments about White-Rodgers 1F89-0211 Non-Programmable Heat Pump Thermostat:
Should be installed in tandem with humidstat since settings when on vacation or extended leave should be based on humitity rather than temp in warm climates, yielding significant savings in cooling.
a single ground in the device may force you to choose between resistance heat in congection with heat pump or battery operation.